Extraction of an Entrapped Guide-Wire with Minimal Invasive Technique: A Case Report
Ali Vefa ÖZCAN1, Harun EVRENGÜL2, Bilgin EMRECAN1, Halil TANRIVERDİ2, İbrahim GÖKŞİN1
1Pamukkale Üniversitesi, Kalp Damar Cerrahisi Anabilim Dalı, DENİZLİ
2Pamukkale Üniversitesi Tıp Fakültesi, Kardiyoloji Anabilim Dalı, Kınıklı DENİZLİ

An escaped guide-wire of subclavian catheter to the venous lumen is a rare complication. In this case, the guide-wire was escaped to the venous lumen from the right subclavian vein while the emergent temporary pace-maker was inserted to the patient with cardiac arrest due to acute myocardial infarction. The guide which was extended from the inferior vena cava to the right iliac vein was established, but it could not be extracted with the right femoral surgical intervention. We wanted to present extraction of an escaped guide from the inferior vena cava via endovascular snare technique in this article.©2008, Firat University, Medical Faculty.